{"links":{},"metadata":{"_oai":{"id":"oai:ipsj.ixsq.nii.ac.jp:00234268","sets":["581:11492:11498"]},"path":["11498"],"owner":"44499","recid":"234268","title":["医療機器の位置稼働状態管理のためのモニタリングシステムの構築と実証"],"pubdate":{"attribute_name":"公開日","attribute_value":"2024-05-15"},"_buckets":{"deposit":"e1381bc2-147f-48da-b31a-b92aba5f4230"},"_deposit":{"id":"234268","pid":{"type":"depid","value":"234268","revision_id":0},"owners":[44499],"status":"published","created_by":44499},"item_title":"医療機器の位置稼働状態管理のためのモニタリングシステムの構築と実証","author_link":["638155","638145","638147","638143","638149","638142","638148","638152","638157","638158","638146","638156","638141","638154","638150","638144","638153","638151"],"item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"医療機器の位置稼働状態管理のためのモニタリングシステムの構築と実証"},{"subitem_title":"Development and Demonstration of Monitoring System for Position and Operation Management of Medical Devices","subitem_title_language":"en"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"[特集:情報システム論文] IoT,医療機器,屋内測位,稼働状態","subitem_subject_scheme":"Other"}]},"item_type_id":"2","publish_date":"2024-05-15","item_2_text_3":{"attribute_name":"著者所属","attribute_value_mlt":[{"subitem_text_value":"名古屋工業大学"},{"subitem_text_value":"名古屋工業大学"},{"subitem_text_value":"名古屋工業大学"},{"subitem_text_value":"名古屋大学"},{"subitem_text_value":"名古屋大学"},{"subitem_text_value":"名古屋大学"},{"subitem_text_value":"名古屋工業大学"},{"subitem_text_value":"名古屋大学"},{"subitem_text_value":"名古屋工業大学"}]},"item_2_text_4":{"attribute_name":"著者所属(英)","attribute_value_mlt":[{"subitem_text_value":"Nagoya Institute of Technology","subitem_text_language":"en"},{"subitem_text_value":"Nagoya Institute of Technology","subitem_text_language":"en"},{"subitem_text_value":"Nagoya Institute of Technology","subitem_text_language":"en"},{"subitem_text_value":"Nagoya University","subitem_text_language":"en"},{"subitem_text_value":"Nagoya University","subitem_text_language":"en"},{"subitem_text_value":"Nagoya University","subitem_text_language":"en"},{"subitem_text_value":"Nagoya Institute of Technology","subitem_text_language":"en"},{"subitem_text_value":"Nagoya University","subitem_text_language":"en"},{"subitem_text_value":"Nagoya Institute of Technology","subitem_text_language":"en"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"publish_status":"0","weko_shared_id":-1,"item_file_price":{"attribute_name":"Billing file","attribute_type":"file","attribute_value_mlt":[{"url":{"url":"https://ipsj.ixsq.nii.ac.jp/record/234268/files/IPSJ-JNL6505003.pdf","label":"IPSJ-JNL6505003.pdf"},"date":[{"dateType":"Available","dateValue":"2026-05-15"}],"format":"application/pdf","billing":["billing_file"],"filename":"IPSJ-JNL6505003.pdf","filesize":[{"value":"5.6 MB"}],"mimetype":"application/pdf","priceinfo":[{"tax":["include_tax"],"price":"660","billingrole":"5"},{"tax":["include_tax"],"price":"330","billingrole":"6"},{"tax":["include_tax"],"price":"0","billingrole":"8"},{"tax":["include_tax"],"price":"0","billingrole":"44"}],"accessrole":"open_date","version_id":"1d94e699-2238-42c9-87df-eebb4621cb25","displaytype":"detail","licensetype":"license_note","license_note":"Copyright (c) 2024 by the Information Processing Society of Japan"}]},"item_2_creator_5":{"attribute_name":"著者名","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"伊藤, 暢浩"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"川北, 崇斗"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"神谷, 寧々"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"相木, 一輝"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"藤井, 雄介"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"加藤, 孝昭"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"島, 孔介"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"大山, 慎太郎"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"大塚, 孝信"}],"nameIdentifiers":[{}]}]},"item_2_creator_6":{"attribute_name":"著者名(英)","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Nobuhiro, Ito","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Shuto, Kawakita","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Nene, Kamiya","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Kazuki, Aiki","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Yusuke, Fujii","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Takaaki, Kato","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Kosuke, Shima","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Shintaro, Oyama","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Takanobu, Otsuka","creatorNameLang":"en"}],"nameIdentifiers":[{}]}]},"item_2_source_id_9":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_source_identifier":"AN00116647","subitem_source_identifier_type":"NCID"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourceuri":"http://purl.org/coar/resource_type/c_6501","resourcetype":"journal article"}]},"item_2_publisher_15":{"attribute_name":"公開者","attribute_value_mlt":[{"subitem_publisher":"情報処理学会","subitem_publisher_language":"ja"}]},"item_2_source_id_11":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"1882-7764","subitem_source_identifier_type":"ISSN"}]},"item_2_description_7":{"attribute_name":"論文抄録","attribute_value_mlt":[{"subitem_description":"医療機器の高度化が進む医療機関では,医療機器を多く使用している.医療機器の管理方法として,最近では病院全体で管理を行う中央管理の手法がとられる.中央管理では,Medical Engineering(ME)センターで機器の点検と保管をし,医療機器の貸出や返却をME機器管理システムで管理している.しかしながら,人がつど,貸出先を登録するシステムでは実際の医療機器の状態とシステムに登録されている状態の間に差異が生じることがあり,病院の中で医療機器が行方不明となってしまうことがある.本研究ではこのような問題を解決するために,リアルタイムに機器の状態を可視化できる医療機器管理システムを開発する.医療機器本体に手を加えることなく様々な機器で使用できるように電波強度を用いた屋内位置推定と医療機器の消費電流に基づいた稼働情報の収集を行うことができる電源タップ型のデバイスを開発する.実際に病院の1つのフロアで医療機器の捜索実験を行い,提案手法を使った場合と使わない場合で医療機器の捜索時間が半分になることを示した.また,収集した医療機器の稼働状況グラフを元に,過剰であった医療機器を再配置し,コスト削減につながることを示した.","subitem_description_type":"Other"}]},"item_2_description_8":{"attribute_name":"論文抄録(英)","attribute_value_mlt":[{"subitem_description":"Many medical devices are used in hospitals where medical care is advanced. As a management method of medical equipment, a central management method that manages the whole hospital is used recently. In the medical engineering (ME) center, Clinical Engineers inspect and store equipment, and the lending and returning of medical equipment is managed by the ME equipment management system. However, in the system where people register each time, there may be a difference between the actual status of medical equipment and the status registered in the system, and medical equipment may go missing in the hospital. In this research, in order to solve such problems, we develop a medical device management system that can visualize the status of devices in real time. We develop a power strip that can perform indoor position estimation using radio wave intensity and collect operation information based on the current consumption of medical equipment so that it can be used with various equipment without modifying the medical equipment. We conducted a search experiment for medical equipment on one floor of a hospital, and showed that the search time for medical equipment was halved when the proposed method was used and when it was not used. In addition, based on the operation status graph of medical equipment, it was shown that the number of excessive medical equipments was reduced, leading to cost reduction.","subitem_description_type":"Other"}]},"item_2_biblio_info_10":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicPageEnd":"913","bibliographic_titles":[{"bibliographic_title":"情報処理学会論文誌"}],"bibliographicPageStart":"903","bibliographicIssueDates":{"bibliographicIssueDate":"2024-05-15","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"5","bibliographicVolumeNumber":"65"}]},"relation_version_is_last":true,"item_2_identifier_registration":{"attribute_name":"ID登録","attribute_value_mlt":[{"subitem_identifier_reg_text":"10.20729/00234151","subitem_identifier_reg_type":"JaLC"}]},"weko_creator_id":"44499"},"created":"2025-01-19T01:36:00.758882+00:00","updated":"2025-01-19T09:49:45.247546+00:00","id":234268}