{"created":"2025-01-19T01:33:50.120991+00:00","updated":"2025-01-19T10:19:33.687173+00:00","metadata":{"_oai":{"id":"oai:ipsj.ixsq.nii.ac.jp:00232775","sets":["1164:5352:11553:11554"]},"path":["11554"],"owner":"44499","recid":"232775","title":["Quick Screening Micro Cognitive Impairment and Dementia using Quantitative Evaluation of Motor Control Function"],"pubdate":{"attribute_name":"公開日","attribute_value":"2024-02-29"},"_buckets":{"deposit":"0e24c5a5-92be-459a-a482-1a4997ee172c"},"_deposit":{"id":"232775","pid":{"type":"depid","value":"232775","revision_id":0},"owners":[44499],"status":"published","created_by":44499},"item_title":"Quick Screening Micro Cognitive Impairment and Dementia using Quantitative Evaluation of Motor Control Function","author_link":["630925","630924","630926","630923","630928","630927"],"item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Quick Screening Micro Cognitive Impairment and Dementia using Quantitative Evaluation of Motor Control Function"},{"subitem_title":"Quick Screening Micro Cognitive Impairment and Dementia using Quantitative Evaluation of Motor Control Function","subitem_title_language":"en"}]},"item_type_id":"4","publish_date":"2024-02-29","item_4_text_3":{"attribute_name":"著者所属","attribute_value_mlt":[{"subitem_text_value":"Niijima Internal Medicine Clinic"},{"subitem_text_value":"Soft CDC Corp."}]},"item_4_text_4":{"attribute_name":"著者所属(英)","attribute_value_mlt":[{"subitem_text_value":"Niijima Internal Medicine Clinic","subitem_text_language":"en"},{"subitem_text_value":"Soft CDC Corp.","subitem_text_language":"en"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_publisher":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"情報処理学会","subitem_publisher_language":"ja"}]},"publish_status":"0","weko_shared_id":-1,"item_file_price":{"attribute_name":"Billing file","attribute_type":"file","attribute_value_mlt":[{"url":{"url":"https://ipsj.ixsq.nii.ac.jp/record/232775/files/IPSJ-BIO24077026.pdf","label":"IPSJ-BIO24077026.pdf"},"date":[{"dateType":"Available","dateValue":"2026-03-01"}],"format":"application/pdf","billing":["billing_file"],"filename":"IPSJ-BIO24077026.pdf","filesize":[{"value":"1.1 MB"}],"mimetype":"application/pdf","priceinfo":[{"tax":["include_tax"],"price":"660","billingrole":"5"},{"tax":["include_tax"],"price":"330","billingrole":"6"},{"tax":["include_tax"],"price":"0","billingrole":"41"},{"tax":["include_tax"],"price":"0","billingrole":"44"}],"accessrole":"open_date","version_id":"007e874e-3f31-48b1-83b7-1077df625509","displaytype":"detail","licensetype":"license_note","license_note":"Copyright (c) 2024 by the Information Processing Society of Japan"}]},"item_4_creator_5":{"attribute_name":"著者名","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Kyota, Aoki"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Kenji, Niijima"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Tsutomu, Yoshioka"}],"nameIdentifiers":[{}]}]},"item_4_creator_6":{"attribute_name":"著者名(英)","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Kyota, Aoki","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Kenji, Niijima","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Tsutomu, Yoshioka","creatorNameLang":"en"}],"nameIdentifiers":[{}]}]},"item_4_source_id_9":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_source_identifier":"AA12055912","subitem_source_identifier_type":"NCID"}]},"item_4_textarea_12":{"attribute_name":"Notice","attribute_value_mlt":[{"subitem_textarea_value":"SIG Technical Reports are nonrefereed and hence may later appear in any journals, conferences, symposia, etc."}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourceuri":"http://purl.org/coar/resource_type/c_18gh","resourcetype":"technical report"}]},"item_4_source_id_11":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"2188-8590","subitem_source_identifier_type":"ISSN"}]},"item_4_description_7":{"attribute_name":"論文抄録","attribute_value_mlt":[{"subitem_description":"The Visual synchronization task (VST) evaluates the motor control function, generates evaluation parameters, and takes only 25 seconds to complete. Evaluation parameters of the VST were tested as predictors of micro cognitive impairment (MCI) and dementia. The mean rotation speed parameter decreased in order of control, MCI, and dementia groups. With the mean rotation speed parameters of right hand in the first period (represented as AveP3rR1), p-value of t-test between the control group and the dementia group is 8.37 × 10-13, and AUC is 0.863. Between the control and dementia groups with 0.765 as a cut-off value of the AveP3rR1, specificity is 0.84 and sensitivity is 0.77. Using the mean rotation speed of the right hand in the first period as the evaluating parameter, the VST can be measured in less than 15 seconds, which enables an easy screening for MCI.","subitem_description_type":"Other"}]},"item_4_description_8":{"attribute_name":"論文抄録(英)","attribute_value_mlt":[{"subitem_description":"The Visual synchronization task (VST) evaluates the motor control function, generates evaluation parameters, and takes only 25 seconds to complete. Evaluation parameters of the VST were tested as predictors of micro cognitive impairment (MCI) and dementia. The mean rotation speed parameter decreased in order of control, MCI, and dementia groups. With the mean rotation speed parameters of right hand in the first period (represented as AveP3rR1), p-value of t-test between the control group and the dementia group is 8.37 × 10-13, and AUC is 0.863. Between the control and dementia groups with 0.765 as a cut-off value of the AveP3rR1, specificity is 0.84 and sensitivity is 0.77. Using the mean rotation speed of the right hand in the first period as the evaluating parameter, the VST can be measured in less than 15 seconds, which enables an easy screening for MCI.","subitem_description_type":"Other"}]},"item_4_biblio_info_10":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicPageEnd":"6","bibliographic_titles":[{"bibliographic_title":"研究報告バイオ情報学(BIO)"}],"bibliographicPageStart":"1","bibliographicIssueDates":{"bibliographicIssueDate":"2024-02-29","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"26","bibliographicVolumeNumber":"2024-BIO-77"}]},"relation_version_is_last":true,"weko_creator_id":"44499"},"id":232775,"links":{}}