{"metadata":{"_oai":{"id":"oai:ipsj.ixsq.nii.ac.jp:00226898","sets":["1164:8666:11217:11288"]},"path":["11288"],"owner":"44499","recid":"226898","title":["Arduinoを用いた筋電情報と低周波刺激装置による高齢片麻痺者の麻痺側の動作生成至適条件に関する研究"],"pubdate":{"attribute_name":"公開日","attribute_value":"2023-07-14"},"_buckets":{"deposit":"b845d030-e504-4244-be82-4f6fd89627ec"},"_deposit":{"id":"226898","pid":{"type":"depid","value":"226898","revision_id":0},"owners":[44499],"status":"published","created_by":44499},"item_title":"Arduinoを用いた筋電情報と低周波刺激装置による高齢片麻痺者の麻痺側の動作生成至適条件に関する研究","author_link":["603365","603368","603366","603367"],"item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Arduinoを用いた筋電情報と低周波刺激装置による高齢片麻痺者の麻痺側の動作生成至適条件に関する研究"},{"subitem_title":"A Study on Optimal Conditions for Generating Motion on the Paralyzed Side in Elderly Hemiplegics Using Myoelectric Information and Low-Frequency Stimulator with Arduino","subitem_title_language":"en"}]},"item_type_id":"4","publish_date":"2023-07-14","item_4_text_3":{"attribute_name":"著者所属","attribute_value_mlt":[{"subitem_text_value":"群馬パース大学大学院保健科学研究科"},{"subitem_text_value":"群馬パース大学リハビリテーション学部理学療法学科"}]},"item_4_text_4":{"attribute_name":"著者所属(英)","attribute_value_mlt":[{"subitem_text_value":"Gunma Paz University Graduate School of Health Sciences","subitem_text_language":"en"},{"subitem_text_value":"Gunma Paz University Faculty of Rehabilitation Department of Physical Therapy","subitem_text_language":"en"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_publisher":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"情報処理学会","subitem_publisher_language":"ja"}]},"publish_status":"0","weko_shared_id":-1,"item_file_price":{"attribute_name":"Billing file","attribute_type":"file","attribute_value_mlt":[{"url":{"url":"https://ipsj.ixsq.nii.ac.jp/record/226898/files/IPSJ-AAC23022003.pdf","label":"IPSJ-AAC23022003.pdf"},"date":[{"dateType":"Available","dateValue":"2025-07-14"}],"format":"application/pdf","billing":["billing_file"],"filename":"IPSJ-AAC23022003.pdf","filesize":[{"value":"2.8 MB"}],"mimetype":"application/pdf","priceinfo":[{"tax":["include_tax"],"price":"660","billingrole":"5"},{"tax":["include_tax"],"price":"330","billingrole":"6"},{"tax":["include_tax"],"price":"0","billingrole":"52"},{"tax":["include_tax"],"price":"0","billingrole":"44"}],"accessrole":"open_date","version_id":"514b35c0-a27d-49cc-abad-e70ad6733959","displaytype":"detail","licensetype":"license_note","license_note":"Copyright (c) 2023 by the Information Processing Society of Japan"}]},"item_4_creator_5":{"attribute_name":"著者名","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"田辺, 将也"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"木村, 朗"}],"nameIdentifiers":[{}]}]},"item_4_creator_6":{"attribute_name":"著者名(英)","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Masaya, Tanabe","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Akira, Kimura","creatorNameLang":"en"}],"nameIdentifiers":[{}]}]},"item_4_source_id_9":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_source_identifier":"AA12752949","subitem_source_identifier_type":"NCID"}]},"item_4_textarea_12":{"attribute_name":"Notice","attribute_value_mlt":[{"subitem_textarea_value":"SIG Technical Reports are nonrefereed and hence may later appear in any journals, conferences, symposia, etc."}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourceuri":"http://purl.org/coar/resource_type/c_18gh","resourcetype":"technical report"}]},"item_4_source_id_11":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"2432-2431","subitem_source_identifier_type":"ISSN"}]},"item_4_description_7":{"attribute_name":"論文抄録","attribute_value_mlt":[{"subitem_description":"脳卒中片麻痺者における Arduino を用いた機能的電気刺激装置の使用による通電至適条件を明らかにすることが目的であった.対象者は健常者 11 名と片麻痺者 10 名であった.手関節最大背屈角度,疼痛,汎用性インデックスをアウトカムとし周波数反応性を比較した.結果は,35Hz 条件では背屈角度が低くなり,120Hz 条件では疼痛が強くなった.また,片麻痺者では汎用性インデックスが最大になる者が 35Hz 条件では少なく,周波数に対する反応性が異なった.生活期の脳卒中片麻痺者では麻痺肢の廃用の程度を考慮した適切な周波数設定が重要であることが示唆された.","subitem_description_type":"Other"}]},"item_4_description_8":{"attribute_name":"論文抄録(英)","attribute_value_mlt":[{"subitem_description":"The purpose of this study was to clarify the optimum conditions for energizing a functional electrical stimulator using an Arduino in hemiplegic stroke patients. The subjects were 11 healthy subjects and 10 hemiplegics. Frequency responsiveness was compared using the maximum dorsiflexion angle of the wrist joint, pain, and versatility index as outcomes. The results showed that the dorsiflexion angle was lower in the 35-Hz condition, and pain was higher in the 120-Hz condition. In addition, fewer hemiplegics had a maximum versatility index in the 35-Hz condition. The results showed different responsiveness to frequency. The results suggest that it is important to set an appropriate frequency for hemiplegic stroke survivors considering the degree of disuse of the paralyzed limb.","subitem_description_type":"Other"}]},"item_4_biblio_info_10":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicPageEnd":"6","bibliographic_titles":[{"bibliographic_title":"研究報告アクセシビリティ(AAC)"}],"bibliographicPageStart":"1","bibliographicIssueDates":{"bibliographicIssueDate":"2023-07-14","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"3","bibliographicVolumeNumber":"2023-AAC-22"}]},"relation_version_is_last":true,"weko_creator_id":"44499"},"id":226898,"updated":"2025-01-19T12:21:11.792822+00:00","links":{},"created":"2025-01-19T01:26:13.197263+00:00"}