{"metadata":{"_oai":{"id":"oai:ipsj.ixsq.nii.ac.jp:00214301","sets":["1164:2735:10526:10756"]},"path":["10756"],"owner":"44499","recid":"214301","title":["呼吸の特徴量を用いた心拍間隔の欠損補完"],"pubdate":{"attribute_name":"公開日","attribute_value":"2021-12-06"},"_buckets":{"deposit":"52c0fadc-3ad7-453c-93fc-487f872d7abe"},"_deposit":{"id":"214301","pid":{"type":"depid","value":"214301","revision_id":0},"owners":[44499],"status":"published","created_by":44499},"item_title":"呼吸の特徴量を用いた心拍間隔の欠損補完","author_link":["549429","549427","549428","549430"],"item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"呼吸の特徴量を用いた心拍間隔の欠損補完"},{"subitem_title":"Missing RR Intervals Complement Using Respiration Features","subitem_title_language":"en"}]},"item_type_id":"4","publish_date":"2021-12-06","item_4_text_3":{"attribute_name":"著者所属","attribute_value_mlt":[{"subitem_text_value":"奈良女子大学"},{"subitem_text_value":"奈良女子大学"}]},"item_4_text_4":{"attribute_name":"著者所属(英)","attribute_value_mlt":[{"subitem_text_value":"Nara Women's University","subitem_text_language":"en"},{"subitem_text_value":"Nara Women's University","subitem_text_language":"en"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_publisher":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"情報処理学会","subitem_publisher_language":"ja"}]},"publish_status":"0","weko_shared_id":-1,"item_file_price":{"attribute_name":"Billing file","attribute_type":"file","attribute_value_mlt":[{"url":{"url":"https://ipsj.ixsq.nii.ac.jp/record/214301/files/IPSJ-MPS21136004.pdf","label":"IPSJ-MPS21136004.pdf"},"date":[{"dateType":"Available","dateValue":"2023-12-06"}],"format":"application/pdf","billing":["billing_file"],"filename":"IPSJ-MPS21136004.pdf","filesize":[{"value":"863.3 kB"}],"mimetype":"application/pdf","priceinfo":[{"tax":["include_tax"],"price":"660","billingrole":"5"},{"tax":["include_tax"],"price":"330","billingrole":"6"},{"tax":["include_tax"],"price":"0","billingrole":"17"},{"tax":["include_tax"],"price":"0","billingrole":"44"}],"accessrole":"open_date","version_id":"c311ed27-a06b-4951-8ac2-c551b29d6e4a","displaytype":"detail","licensetype":"license_note","license_note":"Copyright (c) 2021 by the Information Processing Society of Japan"}]},"item_4_creator_5":{"attribute_name":"著者名","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"野村, 涼子"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"吉田, 哲也"}],"nameIdentifiers":[{}]}]},"item_4_creator_6":{"attribute_name":"著者名(英)","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Ryoko, Nomura","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Tetsuya, Yoshida","creatorNameLang":"en"}],"nameIdentifiers":[{}]}]},"item_4_source_id_9":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_source_identifier":"AN10505667","subitem_source_identifier_type":"NCID"}]},"item_4_textarea_12":{"attribute_name":"Notice","attribute_value_mlt":[{"subitem_textarea_value":"SIG Technical Reports are nonrefereed and hence may later appear in any journals, conferences, symposia, etc."}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourceuri":"http://purl.org/coar/resource_type/c_18gh","resourcetype":"technical report"}]},"item_4_source_id_11":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"2188-8833","subitem_source_identifier_type":"ISSN"}]},"item_4_description_7":{"attribute_name":"論文抄録","attribute_value_mlt":[{"subitem_description":"生体計測の技術の発展により,心拍や呼吸などのモニタリングが容易にできるようになってきた.本稿では,心拍間隔の欠損によるモニタリングの信頼性低減を改善するため,日常的にも計測できる呼吸を用いた心拍間隔の欠損補完を提案する.提案法は,個人ごとに合わせて適切な呼吸の特徴量を選定するとともに,時間的な変動を反映して RRI の欠損補完を実現する.提案法を実装し,RRI の欠損補完に従来から用いられてきたスプライン補間と比較して検証した.","subitem_description_type":"Other"}]},"item_4_description_8":{"attribute_name":"論文抄録(英)","attribute_value_mlt":[{"subitem_description":"Technological advances of bioinstrumentation lead to evolution of monitoring of ECG, respiration. In this paper, we propose a complement method of missing RR Intervals using respiration that enables continuous monitoring for improving unreliable monitoring by missing RR Intervals. The proposed method considers of variation with time and individually selects of respiration features. We verified in comparison with the conventional method of spline interpolation.","subitem_description_type":"Other"}]},"item_4_biblio_info_10":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicPageEnd":"6","bibliographic_titles":[{"bibliographic_title":"研究報告数理モデル化と問題解決(MPS)"}],"bibliographicPageStart":"1","bibliographicIssueDates":{"bibliographicIssueDate":"2021-12-06","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"4","bibliographicVolumeNumber":"2021-MPS-136"}]},"relation_version_is_last":true,"weko_creator_id":"44499"},"id":214301,"updated":"2025-01-19T16:49:51.420949+00:00","links":{},"created":"2025-01-19T01:15:07.470500+00:00"}