{"created":"2025-01-19T00:57:48.416124+00:00","updated":"2025-01-20T00:19:31.621294+00:00","metadata":{"_oai":{"id":"oai:ipsj.ixsq.nii.ac.jp:00192009","sets":["1164:3980:9387:9574"]},"path":["9574"],"owner":"44499","recid":"192009","title":["気圧センサを用いたステップ認識手法"],"pubdate":{"attribute_name":"公開日","attribute_value":"2018-11-08"},"_buckets":{"deposit":"91017f7e-4951-4504-b1c7-e544f4cf6575"},"_deposit":{"id":"192009","pid":{"type":"depid","value":"192009","revision_id":0},"owners":[44499],"status":"published","created_by":44499},"item_title":"気圧センサを用いたステップ認識手法","author_link":["445092","445090","445091","445089"],"item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"気圧センサを用いたステップ認識手法"},{"subitem_title":"Step Recognition Method Using Atmospheric Pressure Sensor","subitem_title_language":"en"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"MBL","subitem_subject_scheme":"Other"}]},"item_type_id":"4","publish_date":"2018-11-08","item_4_text_3":{"attribute_name":"著者所属","attribute_value_mlt":[{"subitem_text_value":"愛知工業大学大学院経営情報情報科学研究科"},{"subitem_text_value":"愛知工業大学情報科学部"}]},"item_4_text_4":{"attribute_name":"著者所属(英)","attribute_value_mlt":[{"subitem_text_value":"Graduate School of Business Administration and Computer Science, Aichi Institute of Technology","subitem_text_language":"en"},{"subitem_text_value":"Aichi Institute of Technology","subitem_text_language":"en"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_publisher":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"情報処理学会","subitem_publisher_language":"ja"}]},"publish_status":"0","weko_shared_id":-1,"item_file_price":{"attribute_name":"Billing file","attribute_type":"file","attribute_value_mlt":[{"url":{"url":"https://ipsj.ixsq.nii.ac.jp/record/192009/files/IPSJ-ITS18075016.pdf","label":"IPSJ-ITS18075016.pdf"},"date":[{"dateType":"Available","dateValue":"2020-11-08"}],"format":"application/pdf","billing":["billing_file"],"filename":"IPSJ-ITS18075016.pdf","filesize":[{"value":"4.7 MB"}],"mimetype":"application/pdf","priceinfo":[{"tax":["include_tax"],"price":"660","billingrole":"5"},{"tax":["include_tax"],"price":"330","billingrole":"6"},{"tax":["include_tax"],"price":"0","billingrole":"37"},{"tax":["include_tax"],"price":"0","billingrole":"44"}],"accessrole":"open_date","version_id":"192bb2f5-48d1-41d9-9d77-348d60f4e2cb","displaytype":"detail","licensetype":"license_note","license_note":"Copyright (c) 2018 by the Information Processing Society of Japan"}]},"item_4_creator_5":{"attribute_name":"著者名","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"磯村, 奎介"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"梶, 克彦"}],"nameIdentifiers":[{}]}]},"item_4_creator_6":{"attribute_name":"著者名(英)","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Keisuke, Isomura","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Katsuhiko, Kaji","creatorNameLang":"en"}],"nameIdentifiers":[{}]}]},"item_4_source_id_9":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_source_identifier":"AA11515904","subitem_source_identifier_type":"NCID"}]},"item_4_textarea_12":{"attribute_name":"Notice","attribute_value_mlt":[{"subitem_textarea_value":"SIG Technical Reports are nonrefereed and hence may later appear in any journals, conferences, symposia, etc."}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourceuri":"http://purl.org/coar/resource_type/c_18gh","resourcetype":"technical report"}]},"item_4_source_id_11":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"2188-8965","subitem_source_identifier_type":"ISSN"}]},"item_4_description_7":{"attribute_name":"論文抄録","attribute_value_mlt":[{"subitem_description":"本研究では気圧センサを利用したステップの認識を行う手法について提案し,歩数推定実験の結果を提示する.現代人はオフィスワーク等の勤務体系から慢性的な運動不足が問題とされており,日常的な運動量を計測する目的として歩数計や運動量を測定するスマートフォンのアプリケーションが普及している.平地を歩行している場合と坂や階段を歩行している場合では運動量が異なるため,加速度センサを用いてステップを測り気圧センサを用いて歩行者の上下方向に対する移動を測定する.つまり歩数計や運動量を測定するアプリケーションでは加速度センサと気圧センサを併用して運動量の計測を行っている.したがって気圧センサを用いたステップ認識が可能となれば,気圧センサを単独で利用した運動量の測定が期待できる.ステップの認識には歩行時に周期的に変化する気圧センサの値を利用する.センサを手に持ち歩行した場合では手の振りによりセンサの高さが推移して気圧センサ値が周期的に変化し,センサをポケットやケースに納めて歩行した場合では歩行動作によりポケットやケースが変形して内部の気圧値が変動するため気圧値が周期的に変化する.気圧値の極大値,極小値の差はある一定値以上発生するため,閾値を設定し極値の差が閾値以上だった場合にステップとして認識する.これらのステップ認識手法の精度を検証するため歩数推定実験を行い,ステップ認識に主流な手法である加速度を用いたステップ認識手法の精度と比較を行った.推定誤差は気圧が 5.2%,加速度が 2.3%,標準偏差は気圧が 2.0 歩,加速度が 1.2 歩となった.","subitem_description_type":"Other"}]},"item_4_biblio_info_10":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicPageEnd":"8","bibliographic_titles":[{"bibliographic_title":"研究報告高度交通システムとスマートコミュニティ(ITS)"}],"bibliographicPageStart":"1","bibliographicIssueDates":{"bibliographicIssueDate":"2018-11-08","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"16","bibliographicVolumeNumber":"2018-ITS-75"}]},"relation_version_is_last":true,"weko_creator_id":"44499"},"id":192009,"links":{}}