{"metadata":{"_oai":{"id":"oai:ipsj.ixsq.nii.ac.jp:00175061","sets":["581:8417:8428"]},"path":["8428"],"owner":"11","recid":"175061","title":["色変換と色照射による可視光で撮影された静脈画像の鮮明化"],"pubdate":{"attribute_name":"公開日","attribute_value":"2016-10-15"},"_buckets":{"deposit":"5908d84d-5c92-4532-90e4-0d3d64c9c3b3"},"_deposit":{"id":"175061","pid":{"type":"depid","value":"175061","revision_id":0},"owners":[11],"status":"published","created_by":11},"item_title":"色変換と色照射による可視光で撮影された静脈画像の鮮明化","author_link":["364034","364033","364032","364029","364031","364036","364035","364030"],"item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"色変換と色照射による可視光で撮影された静脈画像の鮮明化"},{"subitem_title":"Enhancement for Visible Light Photographic Vein Image Using Color Conversion and Color Irradiation","subitem_title_language":"en"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"[一般論文] 静脈,可視光,色変換,色照射,鮮明化","subitem_subject_scheme":"Other"}]},"item_type_id":"2","publish_date":"2016-10-15","item_2_text_3":{"attribute_name":"著者所属","attribute_value_mlt":[{"subitem_text_value":"ユニバーサルロボット株式会社"},{"subitem_text_value":"ユニバーサルロボット株式会社"},{"subitem_text_value":"東京電機大学大学院工学研究科"},{"subitem_text_value":"東京電機大学工学部"}]},"item_2_text_4":{"attribute_name":"著者所属(英)","attribute_value_mlt":[{"subitem_text_value":"Universal Robot Co. Ltd.","subitem_text_language":"en"},{"subitem_text_value":"Universal Robot Co. Ltd.","subitem_text_language":"en"},{"subitem_text_value":"Graduate School of Engineering, Tokyo Denki University","subitem_text_language":"en"},{"subitem_text_value":"School of Engineering, Tokyo Denki University","subitem_text_language":"en"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"publish_status":"0","weko_shared_id":-1,"item_file_price":{"attribute_name":"Billing file","attribute_type":"file","attribute_value_mlt":[{"url":{"url":"https://ipsj.ixsq.nii.ac.jp/record/175061/files/IPSJ-JNL5710021.pdf","label":"IPSJ-JNL5710021.pdf"},"date":[{"dateType":"Available","dateValue":"2018-10-15"}],"format":"application/pdf","billing":["billing_file"],"filename":"IPSJ-JNL5710021.pdf","filesize":[{"value":"2.3 MB"}],"mimetype":"application/pdf","priceinfo":[{"tax":["include_tax"],"price":"660","billingrole":"5"},{"tax":["include_tax"],"price":"330","billingrole":"6"},{"tax":["include_tax"],"price":"0","billingrole":"8"},{"tax":["include_tax"],"price":"0","billingrole":"44"}],"accessrole":"open_date","version_id":"2059d417-fb58-450e-aeb7-258e0c2b00ab","displaytype":"detail","licensetype":"license_note","license_note":"Copyright (c) 2016 by the Information Processing Society of Japan"}]},"item_2_creator_5":{"attribute_name":"著者名","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"岩田, 英三郎"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"釜中, 博樹"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"渡邊, 瑞己"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"長谷川, 誠"}],"nameIdentifiers":[{}]}]},"item_2_creator_6":{"attribute_name":"著者名(英)","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Eizaburo, Iwata","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Hiroki, Kamanaka","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Mizuki, Watanabe","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Makoto, Hasegawa","creatorNameLang":"en"}],"nameIdentifiers":[{}]}]},"item_2_source_id_9":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_source_identifier":"AN00116647","subitem_source_identifier_type":"NCID"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourceuri":"http://purl.org/coar/resource_type/c_6501","resourcetype":"journal article"}]},"item_2_source_id_11":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"1882-7764","subitem_source_identifier_type":"ISSN"}]},"item_2_description_7":{"attribute_name":"論文抄録","attribute_value_mlt":[{"subitem_description":"可視光で撮影された静脈画像の鮮明化について検討する.カラーで撮影された静脈画像の色信号(RGB表色系の赤,緑,青,CMYK表色系のシアン,マゼンダ,イエロー,黒)を混合し,白黒濃淡の静脈画像を生成する方法を提案する.静脈画像と近赤外線で撮影した静脈画像が近似するように,色信号の混合変換における変換係数を調整する.皮膚に特定色の可視光を照射することによって静脈画像を鮮明化する方法を提案する.各種変換係数の調整をシミュレーションし,静脈認証に適用した際の認識率について考察する.","subitem_description_type":"Other"}]},"item_2_description_8":{"attribute_name":"論文抄録(英)","attribute_value_mlt":[{"subitem_description":"Methods of image enhancement for visible light photographic vein image are discussed. We propose methods of color signal blending on a photographic color vein image (RGB color system of red, green, blue, CMYK color system of cyan, magenta, yellow, and black) to generate a grayscale vein image. The coefficients in the blended color signals are adjusted so that the grayscale vein image is approximated to a near infrared vein image. A method of image enhancement by irradiating the specific color of the visible light to the skin is also proposed. The optimization of various transform coefficients for the vein authentication are executed.","subitem_description_type":"Other"}]},"item_2_biblio_info_10":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicPageEnd":"2315","bibliographic_titles":[{"bibliographic_title":"情報処理学会論文誌"}],"bibliographicPageStart":"2307","bibliographicIssueDates":{"bibliographicIssueDate":"2016-10-15","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"10","bibliographicVolumeNumber":"57"}]},"relation_version_is_last":true,"weko_creator_id":"11"},"id":175061,"updated":"2025-01-20T06:21:19.543647+00:00","links":{},"created":"2025-01-19T00:45:06.782471+00:00"}