<?xml version='1.0' encoding='UTF-8'?>
<OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd">
  <responseDate>2026-03-13T13:15:52Z</responseDate>
  <request metadataPrefix="oai_dc" verb="GetRecord" identifier="oai:ipsj.ixsq.nii.ac.jp:00239033">https://ipsj.ixsq.nii.ac.jp/oai</request>
  <GetRecord>
    <record>
      <header>
        <identifier>oai:ipsj.ixsq.nii.ac.jp:00239033</identifier>
        <datestamp>2025-01-19T08:24:58Z</datestamp>
        <setSpec>1164:3980:11478:11711</setSpec>
      </header>
      <metadata>
        <oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns="http://www.w3.org/2001/XMLSchema" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
          <dc:title>寒冷地におけるゼロエミッションデータセンター実現に関する研究</dc:title>
          <dc:title>Research on realization of zero-emission data centers in cold regions</dc:title>
          <dc:creator>山田, 大翔</dc:creator>
          <dc:creator>齋藤, 正史</dc:creator>
          <dc:creator>Hiroto, Yamada</dc:creator>
          <dc:creator>Masashi, Saito</dc:creator>
          <dc:subject>一般講演セッション1</dc:subject>
          <dc:description>北陸地方などの寒冷地におけるデータセンターを想定し，気候特性を利用してデータセンターの熱負荷を軽減し，太陽光発電や蓄電システム等の電力供給により，ゼロエミッションデータセンターの実現性評価を行うシミュレータを開発している．電力削減手法として雪室や外気を用いてサーバを冷却し，有限要素法シミュレータを用いて熱の流れを解析し，需給バランスに与える影響を評価した．太陽光発電量が減少する冬季においても小規模のデータセンターの室温を 27℃ 以下に維持するという制約を満足するために必要な設備を導出した．本シミュレータを用いれば他の環境においても，ゼロエミッションデータセンターの評価が可能になる．</dc:description>
          <dc:description>Assuming a data center in a cold region such as the Hokuriku region, we are developing a simulator to evaluate the feasibility of a zero-emission data center by reducing the heat load of the data center using its climatic characteristics and supplying electricity through solar power generation and energy storage systems. The power reduction method is to cool the servers using snow chambers and outdoor air, and the finite element method simulator is used to analyze the heat flow and evaluate its impact on the supply-demand balance. We derived the equipment required to satisfy the constraint of maintaining the room temperature of a small data center at 27℃ or lower during the winter season, when solar power generation decreases. The simulator can be used to evaluate zero-emission data centers in other environments as well.</dc:description>
          <dc:description>technical report</dc:description>
          <dc:publisher>情報処理学会</dc:publisher>
          <dc:date>2024-09-07</dc:date>
          <dc:format>application/pdf</dc:format>
          <dc:identifier>研究報告高度交通システムとスマートコミュニティ（ITS）</dc:identifier>
          <dc:identifier>2</dc:identifier>
          <dc:identifier>2024-ITS-98</dc:identifier>
          <dc:identifier>1</dc:identifier>
          <dc:identifier>7</dc:identifier>
          <dc:identifier>2188-8965</dc:identifier>
          <dc:identifier>AA11515904</dc:identifier>
          <dc:identifier>https://ipsj.ixsq.nii.ac.jp/record/239033/files/IPSJ-ITS24098002.pdf</dc:identifier>
          <dc:language>jpn</dc:language>
        </oai_dc:dc>
      </metadata>
    </record>
  </GetRecord>
</OAI-PMH>