WEKO3
アイテム
通電信号の知覚認識過程における失明時期の違いが情報の正誤判断の許容誤差に及ぼす皮膚インピーダンスへの影響について
https://ipsj.ixsq.nii.ac.jp/records/226902
https://ipsj.ixsq.nii.ac.jp/records/226902bf789efa-5d95-41f8-af89-a13e83031938
名前 / ファイル | ライセンス | アクション |
---|---|---|
![]()
2025年7月14日からダウンロード可能です。
|
Copyright (c) 2023 by the Information Processing Society of Japan
|
|
非会員:¥660, IPSJ:学会員:¥330, AAC:会員:¥0, DLIB:会員:¥0 |
Item type | SIG Technical Reports(1) | |||||||
---|---|---|---|---|---|---|---|---|
公開日 | 2023-07-14 | |||||||
タイトル | ||||||||
タイトル | 通電信号の知覚認識過程における失明時期の違いが情報の正誤判断の許容誤差に及ぼす皮膚インピーダンスへの影響について | |||||||
タイトル | ||||||||
言語 | en | |||||||
タイトル | The Effect of the Difference in the Time of Blindness in the Perceptual Recognition Process of Electric Current Signals on the Tolerance of Correct and Incorrect Judgment of Information on Skin Impedance | |||||||
言語 | ||||||||
言語 | jpn | |||||||
資源タイプ | ||||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_18gh | |||||||
資源タイプ | technical report | |||||||
著者所属 | ||||||||
群馬パース大学大学院保健科学研究科 | ||||||||
著者所属(英) | ||||||||
en | ||||||||
Graduate School of Health Sciences, Gunma Paz University | ||||||||
著者名 |
木村, 朗
× 木村, 朗
|
|||||||
著者名(英) |
Akira, Kimura
× Akira, Kimura
|
|||||||
論文抄録 | ||||||||
内容記述タイプ | Other | |||||||
内容記述 | 背景と目的 失明者が人との衝突を防止するための情報機器として,センサーと通電信号(ES)を組み合わせた装置の利活用を提案している.人が接近してくる場合と,離れていく場合の鑑別判断の成功確率において先天性と後天性失明者の違いによって,判断に影響を与える通電信号の誤った読み取りを引き起こす緊張性発汗現象に伴う皮膚インピーダンスの変化に違いがある可能性が示唆されるため,これらを定量的に測定し,その差をあきらにすることを目的とした.将来的にアルゴリズムの工夫と吸湿性電極の使用等による成功確のを向上を目指している.対象と方法 本研究デザインは,実験的介入研究およびランダム化比較試験であった.研究期間は,2021 年 8 月から 2022 年 12 月.地域の公民館的公共スペースにてフィールド実験を実施した.参加者は先天性失明者 5 名,後天性失明者 2 名,健常者 2 名.神経疾患に対する治療中である場合,除外された.介入方法は超音波センサーで検出された距離データを,自作の MESH を用いたプログラムにより iPad と BPIO で接続された低周波通電装置を用いて,人が近づく時のみ通電器の信号間隔を変化させた.2 回ほどデモを行った後,各条件をランダムな条件を設定し 10 回試行した.この条件を介入とした.プラセボ条件(常に微弱電流で,センサーの反応を反映しない通電のみ)を無作為に選択し,盲検法で割り付けた.結果は,ES による人接近の判断の成功率が 80% 以上になる条件でのインピーダンス変動の平均値は,先天性失明者と後天性失明者の最小感知電位出力において p<.05 と有意差を認めた.結論 先天性失明者と後天性失明者において通電信号による外界環境の認識・判断のための感覚入力装置と情報処理において,緊張性発汗現象に伴う皮膚インピーダンスの変化に違いがあることが示された.通電信号による外界情報判断支援機器の実装において考慮すべき条件の 1 つと考えられた. | |||||||
論文抄録(英) | ||||||||
内容記述タイプ | Other | |||||||
内容記述 | Background and Objectives We propose the utilization of a device that combines a sensor and an energizing signal (ES) as an information device to prevent blind people from colliding with other people. The difference between congenital and acquired blindness in the probability of success in discriminating between a person approaching and moving away from a person suggests the possibility that there are differences in skin impedance changes associated with the phenomenon of catatonic sweating, which causes incorrect readings of the energizing signal that affect judgment, The purpose of this study was to clarify the difference. The aim is to obtain the optimal conditions under which the use of hygroscopic electrodes could improve the probability of success in the future. Subjects and Methods The study design was an experimental intervention study and a randomized controlled trial. The study period was from August 2021 to December 2022. A field experiment was conducted in a local community center-like public space. Participants included 4 congenitally blind, 2 acquired blind, and 3 healthy subjects. Inclusion criteria were treatment for neurological diseases. The intervention method was to use distance data detected by an ultrasonic sensor and a low-frequency energizer connected to an iPad by BPIO using a home-made MESH program to change the signal interval of the energizer only when a person approached. This condition was used as the intervention. The placebo condition (always a weak current and only energization that did not reflect the sensor's response) was randomly selected and assigned in a blinded fashion. Results showed that the mean impedance variability in the condition that resulted in >80% success rate in judging human proximity by ES was significantly different, p<.05, in the minimal sensing potential output between congenitally blind and acquired blind subjects. Conclusions The results showed that there were differences in skin impedance changes associated with the phenomenon of catatonic sweating between congenitally blind and acquired blind subjects in sensory input devices and information processing for recognizing and judging the external environment by energizing signals. This was considered to be one of the conditions that should be considered in the implementation of a device to support judgment of information on the external environment using electric current signals. | |||||||
書誌レコードID | ||||||||
収録物識別子タイプ | NCID | |||||||
収録物識別子 | AA12752949 | |||||||
書誌情報 |
研究報告アクセシビリティ(AAC) 巻 2023-AAC-22, 号 7, p. 1-5, 発行日 2023-07-14 |
|||||||
ISSN | ||||||||
収録物識別子タイプ | ISSN | |||||||
収録物識別子 | 2432-2431 | |||||||
Notice | ||||||||
SIG Technical Reports are nonrefereed and hence may later appear in any journals, conferences, symposia, etc. | ||||||||
出版者 | ||||||||
言語 | ja | |||||||
出版者 | 情報処理学会 |